Quantcast
Channel: LabWindows/CVI topics
Viewing all articles
Browse latest Browse all 5340

New Bug in CVI2013SP1?

$
0
0

Hello,

 

In CVI2013 there was a bug () when changing the uir file: the change did not show up, one needed to rebuild the project, this seems to have been fixed, but now there is something else... 

 

I have a project with several source files and one UIR file. All source files are compiled, so when pressing the green triangle button the project starts immediately, i.e. the only message shown in the Build Output window is Build succeeded.

 

Now I change one attribute in the UIR file (say the panel title).

 

Scenario A: After modifying my UIR I press the 'save disk' symbol to save the uir file, and only then press the green triangle button. The build action taken is Linking the project, and the program shows the correct UIR. So this is fine.

 

Scenario B: After modifying my UIR I press the green triangle button, CVI then prompts me that the UIR has been modified and needs to be saved. Pressing the OK button then is very time consuming because in this case CVI recompiles all source files, links them, i.e. it seems to perform a complete rebuild... This I would consider a waste of my time and not as expected

:smileyfrustrated:

Well, there is a workaround (scenario A), but I suggest to include a fix in SP2 :smileywink:


Viewing all articles